AC Size Chart: Find Your BTU by Room Size
This AC size chart gives you a starting BTU figure for any space based on square footage. Find your room size, read across, and you have a baseline.
The quick rule is about 20 BTU per square foot, but the charts below break it down in more detail and by room type, which is faster than doing the math. Use it as a lookup table, then adjust for your climate, ceiling height and sun.
Find your room’s square footage on the chart and read across to the BTU and tonnage. A 150 to 250 sq ft bedroom starts at 6,000 BTU, a 450 to 550 sq ft studio at 12,000 BTU (1 ton), and a 1,500 to 2,000 sq ft home at about 30,000 BTU (2.5 tons). Then adjust for ceilings, sun and climate.
This page is a reference table. If you want to understand how the numbers are calculated, with worked examples, read our guide on what size air conditioner you need. If you are comparing efficiency, our SEER rating guide explains that side.
How to Read the AC Size Chart
Every chart below works the same way. Measure the room (length times width), find that number in the first column, and read across to the BTU and tonnage.
Pick the row where your square footage falls. If you land exactly on a boundary, such as 250 sq ft, check the adjustments further down before choosing the smaller or larger size.
Square footage covers one room, not a whole floor. For a window unit or mini split, measure only the space it will cool. For a central system, use the home’s total conditioned area.
Main AC Size Chart: BTU and Tonnage by Square Feet
| Room Size (sq ft) | Room Size (m²) | Recommended BTU | Tonnage |
|---|---|---|---|
| 100 – 150 | 9 – 14 | 5,000 | N/A |
| 150 – 250 | 14 – 23 | 6,000 | N/A |
| 250 – 300 | 23 – 28 | 7,000 | N/A |
| 300 – 350 | 28 – 33 | 8,000 | N/A |
| 350 – 400 | 33 – 37 | 9,000 | N/A |
| 400 – 450 | 37 – 42 | 10,000 | N/A |
| 450 – 550 | 42 – 51 | 12,000 | 1 ton |
| 550 – 700 | 51 – 65 | 14,000 | N/A |
| 700 – 1,000 | 65 – 93 | 18,000 | 1.5 tons |
| 1,000 – 1,200 | 93 – 111 | 21,000 | N/A |
| 1,200 – 1,400 | 111 – 130 | 23,000 | ~2 tons |
| 1,400 – 1,500 | 130 – 139 | 24,000 | 2 tons |
| 1,500 – 2,000 | 139 – 186 | 30,000 | 2.5 tons |
| 2,000 – 2,500 | 186 – 232 | 34,000 | ~3 tons |
| 2,500 – 3,000 | 232 – 279 | 36,000 | 3 tons |
Where the tonnage column shows N/A, the BTU size does not match a common whole or half ton. Those sizes are mostly sold as window or portable units, which are labeled in BTU.
Tons and BTU measure the same thing. One ton equals 12,000 BTU per hour. Window and portable units are usually labeled in BTU; central systems and mini splits in tons.
AC Size by Room Type
Sometimes it’s easier to find your space by what it is than by measuring it.
| Space | Typical Size | Starting BTU |
|---|---|---|
| Small bedroom or office | 100 – 150 sq ft | 5,000 |
| Standard bedroom | 150 – 250 sq ft | 6,000 |
| Large bedroom | 250 – 300 sq ft | 7,000 |
| Small living room | 300 – 350 sq ft | 8,000 |
| Living room | 350 – 450 sq ft | 9,000 – 10,000 |
| Studio apartment | 450 – 550 sq ft | 12,000 |
| Open living and kitchen | 550 – 700 sq ft | 14,000 + kitchen adj. |
| Small home or large open area | 700 – 1,000 sq ft | 18,000 |
| One-bedroom apartment | 600 – 800 sq ft | 14,000 – 18,000 |
| Two-bedroom apartment | 800 – 1,100 sq ft | 18,000 – 21,000 |
Apartments and open layouts are the trickiest rows. Rooms without walls share air, so measure the whole connected space, not just the corner where the unit sits.
Tonnage Chart for Central Systems
For whole-house central systems, capacity is usually discussed in tons.
| Home Size (sq ft) | Home Size (m²) | Approximate Tonnage |
|---|---|---|
| 600 – 1,000 | 56 – 93 | 1.5 – 2 tons |
| 1,000 – 1,500 | 93 – 139 | 2 – 2.5 tons |
| 1,500 – 2,000 | 139 – 186 | 2.5 – 3 tons |
| 2,000 – 2,500 | 186 – 232 | 3 – 3.5 tons |
| 2,500 – 3,000 | 232 – 279 | 3.5 – 4 tons |
| 3,000 – 3,500 | 279 – 325 | 4 – 5 tons |
The tonnage ranges are wider than the room-by-room chart because whole homes vary a lot. Insulation, window area and the number of floors can move a house to either end of its range.
For a whole-house central system, this chart is a rough starting point only. Proper sizing requires a Manual J load calculation that accounts for insulation, windows, air leakage and local climate. A contractor who sizes by square footage alone is guessing, and getting it wrong locks in years of poor comfort.
Window Unit Size Chart
Window units are labeled in BTU, and the main chart applies directly.
| Room Size (sq ft) | BTU | Common Rating |
|---|---|---|
| 100 – 150 | 5,000 | 5,000 |
| 150 – 250 | 6,000 | 6,000 |
| 250 – 350 | 7,000 – 8,000 | 8,000 |
| 350 – 450 | 9,000 – 10,000 | 10,000 |
| 450 – 550 | 12,000 | 12,000 |
| 550 – 700 | 14,000 | 14,000 |
Before buying a window unit, confirm your window opening fits the unit’s dimensions and that the circuit can handle it. Units above about 12,000 BTU often need a dedicated 240-volt circuit rather than a standard outlet.
Portable Unit Size Chart
Portable units are less efficient in practice than their BTU rating suggests, because the exhaust hose radiates heat back into the room and the unit pulls in warm air to replace what it exhausts. Size up.
| Room Size (sq ft) | Window Unit BTU | Portable Unit BTU |
|---|---|---|
| 150 – 250 | 6,000 | 8,000 |
| 250 – 350 | 8,000 | 10,000 |
| 350 – 450 | 10,000 | 12,000 |
| 450 – 550 | 12,000 | 14,000 |
Portable air conditioner ratings can be confusing because two standards exist. The older ASHRAE rating produces a higher number than the newer DOE rating for the same unit. If you see two BTU figures on one unit, the lower DOE figure is the more realistic one for sizing.
Mini Split Size Chart
Mini splits are labeled in BTU or tons, and the main chart applies. For multi-zone systems, each indoor head is sized for its room.
| Room Size (sq ft) | BTU | Common Rating |
|---|---|---|
| 150 – 350 | 9,000 | 9,000 (0.75 ton) |
| 350 – 550 | 12,000 | 12,000 (1 ton) |
| 550 – 800 | 18,000 | 18,000 (1.5 tons) |
| 800 – 1,200 | 24,000 | 24,000 (2 tons) |
Our guide on mini split vs window vs portable units covers the tradeoffs between these types.
Adjustments for Climate, Ceiling Height and Sun
The charts assume an average room: 8-foot ceilings, moderate sun, two occupants, average insulation. Use the table below to move your number up or down.
| Factor | Adjustment |
|---|---|
| 10-foot ceilings | +25% |
| 9-foot ceilings | +12% |
| Heavily sunlit room | +10% |
| Heavily shaded room | −10% |
| Kitchen | +4,000 BTU |
| Each occupant over 2 | +600 BTU |
| Hot, humid climate | +10 to 20% |
| Mild climate | −10% |
| Poor insulation | +10 to 20% |
Quick example: a 300 sq ft room (8,000 BTU base) that’s heavily sunlit (+10%) in a hot climate (+15%) comes to about 10,000 BTU. Round to the nearest available size.
Climate
Hot, humid regions ask more of an AC, because it must remove moisture as well as heat. Mild climates ask less. Pick the adjustment that matches your summers, not the national average.
Ceiling Height
Taller ceilings mean more air to cool. A room with vaulted or 10-foot ceilings can need a full size step up from the chart, even though the floor area is the same.
Sun Exposure and Insulation
Big west-facing windows and a thin attic or wall insulation add heat all afternoon. Shade trees, blinds and good insulation do the opposite and can justify the lower end of a range.
Bigger is not better. When your adjusted number falls between two standard sizes, lean toward the smaller one unless you have a clear reason to size up, like a west-facing room. Oversizing causes short cycling, poor humidity control and a house that feels cold and clammy. It’s the more common and more costly mistake.
If a unit turns on and off every few minutes, read our guide to AC short cycling. For the full sizing method, see the sizing guide.
Quick Conversions: BTU to Tons
| BTU | Tons | Rough Room Size |
|---|---|---|
| 6,000 | 0.5 | 250 sq ft |
| 12,000 | 1 | 550 sq ft |
| 18,000 | 1.5 | 1,000 sq ft |
| 24,000 | 2 | 1,400 sq ft |
| 30,000 | 2.5 | 1,800 sq ft |
| 36,000 | 3 | 2,200 sq ft |
| 48,000 | 4 | 2,800 sq ft |
| 60,000 | 5 | 3,500 sq ft |
To convert BTU to tons: divide by 12,000. To convert tons to BTU: multiply by 12,000.
When to Call a Pro
- Whole-house replacement. Ask for a Manual J load calculation, not a square-footage guess.
- Rooms that never cool evenly. Ductwork or airflow may be the issue, not the unit size.
- Electrical questions. Larger window units may need a dedicated circuit, so have an electrician check.
- Existing system that short cycles. A technician can tell whether it is oversized or has another fault. Our service schedule guide explains routine checkups.
Frequently Asked Questions
What size AC do I need for a 12×12 room?
A 12×12 room is 144 square feet, which calls for about 5,000 to 6,000 BTU as a baseline. Add 10 percent if it gets heavy afternoon sun, and adjust up in a hot climate.
How many BTU do I need for 1,000 square feet?
About 18,000 to 21,000 BTU for 1,000 square feet, or roughly 1.5 to 2 tons. Ceiling height, climate and sun exposure shift this, and a whole-house system at that size should get a proper load calculation.
What size AC for 1,500 square feet?
Around 24,000 to 30,000 BTU, or 2 to 2.5 tons. A hot, humid climate with high ceilings pushes toward the upper end; a mild climate with good insulation toward the lower end.
How do I convert BTU to tons?
Divide the BTU figure by 12,000. A 24,000 BTU system is 2 tons, and 36,000 BTU is 3 tons. The unit comes from how much cooling a ton of melting ice provides over a day.
Why do portable AC units need more BTU?
Because they’re less efficient in practice. The exhaust hose radiates heat back into the room, and the unit creates negative pressure that draws warm air in from elsewhere. Size a portable unit roughly 10 to 20 percent larger than a window unit for the same room.
Should I round up to the next size?
Generally no. When your adjusted figure falls between two sizes, the smaller one is usually the better choice. Oversizing leads to short cycling and poor humidity control, which is a more common problem than undersizing.
Is this chart accurate for a whole house?
It’s a rough starting point for a whole house, but central systems should be sized with a Manual J load calculation. That accounts for insulation, window area and orientation, air leakage and climate in ways a square-footage chart can’t.
How many tons is a 12,000 BTU air conditioner?
A 12,000 BTU air conditioner is 1 ton. On the main chart it fits a room of about 450 to 550 square feet, such as a studio apartment.
Does a higher SEER rating change the size I need?
No. SEER measures efficiency, not cooling capacity, so size comes from the load of your space. Learn more in our SEER rating guide.
Bottom Line
Find your room size on the main chart, note the BTU, then apply any adjustments for ceiling height, sun, kitchen, occupants and climate. If the result lands between two sizes, lean smaller.
For window, portable and mini split units, the charts here get you to the right size directly, remembering that portables need sizing up.
For a whole-house central system, treat any chart as a starting point only and insist on a Manual J calculation. Our thermostat settings guide can then help you run the right-sized system comfortably.